Magnetic field intensity mode |
Measures relative field homogeneity |
|
NMR signal amplitude mode |
No magnetic field modulation required |
|
Only one probe required(0.76-19.3kG range) |
Tracks extremely fast changing fields |
|
Axial/Transverse measurements up to 13T(130kG) |
Correction signal for magnetic field control |
|
Thinnest flexible probe available on the market |
RS-232 communications software |
|
Wireless data transmission (optional) |
|
Specification
|
Field range ------------------------------------------ |
760G-19.3kG (76mT-1930mT) * middle probe |
|
Searching rate (max) ------------------------------- |
50μG/s |
|
Tracking rate (max) -------------------------------- |
90μG/s |
|
Resolution |
0.001G (0.1Μt) |
|
Response time (while tracking)-------------------- |
20-120ms |
|
Absolute Accuracy---------------------------------- |
+/- 5.0ppm |
|
Relative Accuracy----------------------------------- |
+/- 0.1ppm |
|
NMR signal amplitude resolution----------------- |
>0.5% |
|
Field gradient tolerance----------------------------- |
0.02%/cm |
|
Correction signal(for magnetic field control)---- |
Digital value plus sign from any magnetic filed chosen |
|
Probe dimensions------------------------------------ |
Diameter-8mm , length - 41mm |
|
Display ----------------------------------------------- |
20 characters, one line LCD with backlight |
|
Communication ports------------------------------- |
RS-232 and IEEE-488 |
|
OCXO crystal oscillator with: |
|
|
Clock accuracy --------------------------------- |
0.01ppm /day ** |
|
Clock aging stability -------------------------- |
2.0 ppm /year |
|
Cable, measurement head -------------------------- |
300cm |
|
Power requirements -------------------------------- |
115V/230V, 20W , 50/60 Hz |
|
Dimensions ------------------------------------------ |
258(mm) x 102(mm) x 312 (mm) |
|
Weight (with head) |
5.9 kg |
|
|
|
Note: * one probe only. Eight automatic subranges
** after 30 minute warm-up
|
Low field probe ------------------------------------- |
Field range –320G to 780G (32mT – 78mT) Probe length – 10.6mm |
|
High field axial probe ------------------------------ |
Field range –18kG to 130kG and 8kG span Probe length – 12.0mm |
|
High field transverse probe (with heavy water tip)------------------PROBE 1 -------------------PROBE 2 |
Field range –17kG to 30kG (1.47T– 3T) Field range –18kG to 130kG (1.47T– 13T) |
|
Miniaturized probe --------------------------------- |
Field range –0.8kG to 15kG (0.08 T– 1.5T) Diameter- 5.0mm , length- 80mm |
|
Holder, special, measurement head --------------- |
Adaptable for client electromagnet |
|
Converter, RS232 / RS-485 ------------------------ |
For long distance data transmission |
|
Modem , radio -------------------------------------- |
Radio modem for RS-232C port (200m wireless transmission to PC equipment with the same modem) |
|
Software , MAG – PRO ---------------------------- |
For computer control, data acquisition and data processing. |
|
Cable , measurement head to instrument -------- |
Custom dimension up to 39ft. (12m) |
Note: special range and probes can be quoted on request.
Due to continuous process improvement, specifications are subject to change without notice.
|
如有关于本公司产品的问题或建议,请向sale@gaussmeter.com.cn发邮件。 |